4 x 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input Modbus TCP Remote IO Device with MQTT and 868MHz LoRaWAN Connectivity, 2x 10/100 T(x) ETH ports
HUR1813
4 x 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input Modbus TCP Remote IO Device with MQTT and 868MHz LoRaWAN Connectivity, 2x 10/100 T(x) ETH ports
per one
446.50 USD 470 USD
If you buy less than 5 items you will lose your 5% discount
-    4 Slots x 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input
-    Supports 2 x 10/100Base-T(X) ports
-    Supports Full/Half-Duplex, auto MDI/MDI-X on each port
-    Embedded web interface for ease of use
-    Radio Band Options:
868MHz
EU 868 MHz – Europe, LoRaWAN RF Communication
-    LoRaWAN data send interval configurable
-    MQTT Publisher with different data transfer options
     Parsed Data as Data Objects
     Parsed Data as Modbus Frame

-    Built in LoRaWAN Duty Cycle Check
-    Activation Over Air (OTAA) or Activation by Personalization (ABP) Selectable
-    User defined LoRAWAN Port
-    Adaptive Data Rate functionality
-    Selectable Uplink Data Rate
-    Selectable Power Level
-    LoRaWAN Class C and Class A support
-    Easy to follow Device Status on web interface
-    Easy to follow LoRaWAN packages on web interface 
-    Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
-    Easy to follow Modbus data packages on web interface 
-    Instant switch between Server-Client Operating Modes with buttons
-    Up to 10 client connection in Server Mode
-    DHCP Server Capability
-    Device Address changeable via web interface
-    Black List and White List based IP Filter in TCP Server Mode
-    Firmware Upgrade over Web
-    2 firmware storage capability on same device (1 active only)
-    100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC wide range power input
-    Wide operating temperature range from -25 to 70 °C
-    Rugged Metal IP-40 housing design
-    DIN-Rail mounting
TECHNOLOGY
LoRa TECHNOLOGY

Based on 
STM32L151CxU6Axx
Pre-Certified according to EN 300 220
Sensitivity 
Down to -138 dBm
Link Budget 
Up to 156 dB
Communication Distance 
Up to 15km (Line of Sight)
Typical Communication Distance Indoor/Urban
>2km
LoRaWAN Activation Options 
Activation Over Air (OTAA)
Activation by Personalization (ABP)
User Selectable
LoRaWAN Port
User Selectable
Adaptive Data Rate
Available
Uplink Data Rate 
SF12 / 125 kHz / 250 bps
SF11 / 125 kHz / 440 bps
SF10 / 125 kHz / 980 bps
SF9 / 125 kHz / 1760 bps
SF8 / 125 kHz / 3125 bps
SF7 / 125 kHz / 5470 bps
SF7 / 250 kHz / 11000 bps
FSK 50k / NA / 50000 bps
Tx Power Level 
0 to 16dBm Configurable
LoraWAN Class 
Class A
Class C
LoraWAN Data Send
Interval defined by user
Data Format as Modbus Frame

ETHERNET SWITCH TECHNOLOGY

Ethernet Standards 
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X)
IEEE 802.3x Flow Control
Mac Table 
1K MAC address entry
Processing 
Store-and-Forward
Memory 
448K bits packet buffer memory


LoRaWAN, MODBUS and MQTT DETAILS
LoRaWAN DETAILS
Status Message - Device Status
Message sent to LoRaWAN Port number 1 in every connection to LoRaWAN Server
4 Bytes: HUR Device Id
1 Byte: Frame Type (Lower 4 bits) and Package Number (Upper 4 bits). If Package Number is 1 or more that means the package splitted.
0x00 : means status package for device status and package is the first package
1 Byte: Number of I/O Slots available in HUR device
1 Byte for each Slot (4 bytes for 4 Slots): Slot Types available in HUR device
Available Options: 'HUR_8_DIGITAL_IN', 'HUR_8_DIGITAL_OUT', 'HUR_8_ANALOG_IN', 'HUR_5_ANALOG_OUT'
1 Byte: LoRaWAN target port for I/O data
4 Bytes: RTC Time
3 Bytes: HUR Device firmware version
N Bytes (maximum 22): LKM Device name configured by user


I/O Data Message

Message sent to LoRaWAN configured port and minimum send interval can be configured by user

4 Bytes: HUR Device Id
1 Byte: Frame Type (Lower 4 bits) and Package Number (Upper 4 bits). If Package Number is 1 or more that means the package splitted.
0x02 : means meter data package and package is the first package
4 Bytes: RTC Time
1 Byte: Number of I/O Slot which the data is shared
1 Byte: Type of I/O Slot which the data is shared
1 Byte: Total number of bytes in Payload
1 Byte For 'HUR_8_DIGITAL_IN' and 'HUR_8_DIGITAL_OUT' Slots
16 Bytes for 'HUR_8_ANALOG_IN' Slots
10 Bytes for 'HUR_5_ANALOG_OUT' Slots


MODBUS DETAILS
Protocol
Modbus TCP
Modbus Address
Default value is 0x01
Changeable via Web Interface
Save Output Values Before Auto Restart
Default enabled and when system auto restarts the values are saved and applied after restart
Save Output Values and Apply on Power Up
Default disabled, user can activate and enter parameters for each output individually
Changeable via Web Interface
I/O Mirror Functionality
Default disabled
If enabled, device can read input value of remote HUR device and duplicate those values as output
Monitoring Parameters
Modbus Read counter
Time counter (in seconds)
FW version
Device Up Time
TCP packages


MQTT DETAILS
MQTT Publisher can be enabled and can be used in parallel with Modbus conversion (or stand alone)
MQTT Connection
Broker IP and Port can be entered
Client ID , User name and Password can be set
Publish Topic and Subscribe Topic can be defined from web interface
Data Send Interval
User can send Data send interval in seconds
Default is 60 seconds and HUR will send meter data to MQTT server in that interval

NTP Server
NTP server time will be added to each MQTT message

Data Format
There are 2 predefined formats
Parsed Data As Objects: Sends I/O values in ASCII readable fromat
Parsed Data as Modbus Frame: Send just like the response of Modbus query as hex data (smaller data size)


CONNECTORS AND PORTS
SMA Antenna Connector for LoRa
1 Standard SMA female interface, 50 ohm
Console Port
USB Type C or Micro USB connection for LOG in 115200 baud
10/100T(X) RJ45 Ports
Ethernet Connection on 2 ports
Reset Buttons
Reset to Client and Reset to Server Operating modes buttons


INPUT CONNECTORS AND INDICATORS
I/O Connectors
Terminal Connectors
Digital Inputs: 4 Slots x  8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input
8 Channel Input terminals and polarity is not important. 2 pins for each connection and total 16 connection pins for each slot.
12-275 AC-DC, 60mA Digital Optocoupler Inputs.

Isolation
Digital Optocoupler Input:
4470Vrms 1min

Over Voltage Protection
Digital Optocoupler Input:
275V


LED INDICATORS
Power Indicator
Power LED
10/100T(X) Indicators
Activity LEDs:
ETH1, ETH2 and HUR (Activity of device itself)
System Indicators
Status LED,
Tx and Rx of data LEDs and Server LED
(LED ON: Server Operating Mode, LED OFF: Client Operating Mode)

Slot LEDs

S-1, S-2, S-3 and S-4: Turns On for 1 second and Turns OFF for 1 second under normal operation of I/O Interface.
Each LED corresponds to related I/O Slot.

Console Indicators

Tx and Rx of data LEDs



POWER
Input Range
100 - 240V AC (120 – 370V DC), 50Hz to 60Hz Wide Range AC Power Input
Isolation
Fully Isolated >4200Vrms, 5mA 1 Min
Insulation
Class II


PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
Enclosure
Metal, IP 40
Dimensions
115 x 970 x 126 (w x d x h) mm
Weight
~700gr
Storage Temperature
-40 to 105 °C 

Operating Temperature
-25 to 70 °C 

Operating Humidity
5% to 95%Non-condensing


HUR1813: Multi Slot, 4 x 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input Modbus TCP Remote IO Device with MQTT and 868MHZ LoRaWAN Connectivity, 2x 10/100 T(x) ETH ports, 100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC Power Input
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
TLM Series LoRa Modems and LoRaWAN EndNode Modems
TLM Series LoRa Modems and LoRaWAN EndNode Modems
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
KMK Series Optical Probes for Energy Meters
HUR Series Modbus TCP and RTU Remote I/O Devices with MQTT (and LoRaWAN)
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
MBC Series IEC62056-21 Protocol Auto Baud Changer
KMK Series Optical Probes for Energy Meters
REDZ Software Solutions