- 8 Channel 5-275V AC-DC, 100mA Digital Optocoupler Output
- Modbus address 1 to 247, changeable with Modbus RTU commands
- Easy to monitor device parameters such as up time, read counter and firmware version, plus a diagnostic block with frame and error counters
- Modbus RTU over RS485: 9600 to 230400 bit/s, 8N1, 8E1 or 8O1 (default 115200 8N1)
- ZTerminal for Windows: configuration and monitoring software
- Firmware update over the RS485 line (see the user manual)
- Write lock for all settings
- Communication watchdog: outputs go to user-defined safe values when the master stops polling
- Output values are kept over the automatic restart (every 1 to 255 h, default 24 h)
- Output values at power up can be set per output with Modbus commands
- 9-48V DC wide range power input, polarity-independent
- Wide operating temperature range from -40 to 85 C
- Rugged metal IP40 housing
- DIN rail mounting
MODBUS RTU DETAILS - HUR OUTPUT MODELS
Protocol
Modbus RTU, function codes 01, 02, 03, 04, 05, 06, 15 and 16; broadcast writes to address 0
Line Settings
9600, 19200, 57600, 115200 or 230400 bit/s; 8N1, 8E1 or 8O1; default 115200 8N1; settings take effect after the next start
Modbus RTU Address
Default value is 1 (1 to 247)
Changeable via Modbus Command
Save Output Values Before Auto Restart
Default is enabled: at the automatic restart (every 1 to 255 h, default 24 h, 0 = off) the output values are kept and applied after the restart
Changeable via Modbus Command
Save Output Values and Apply on Power Up
Default is disabled; the power-up value of each output can be set individually
Communication Watchdog
1 to 3600 s (0 = off, default); a safe value or "keep the last value" per output
Changeable via Modbus Command
Monitoring Parameters
Modbus RTU read counter, up time (in seconds), firmware date and version
Diagnostic Block
Received frames, CRC, parity, framing and buffer errors, restart cause
Write Lock
Locks all settings (address, speed, watchdog, input settings)
I/O TERMINAL AND INDICATORS - 8 Channel Digital Optocoupler Output
I/O Connectors
Terminal Connectors
Digital Outputs: 8 channels, output terminals polarity is not important
2 pins for each channel, total 16 connection pins
5-275V AC/DC, 100mA Digital Optocoupler Outputs
Isolation
Digital Optocoupler Output:
3750 Vrms for 1 min
Over Voltage Protection
Digital Optocoupler Output: 275V
Non-repetitive peak on-state pulse current: 80A
Output Status LEDs
Shows which output is ON and OFF
INTERFACE, INDICATORS AND FIRMWARE UPGRADE
RS485 Terminal
Terminal Connector for 2 wire RS485 connection and GND.
Activity LEDs
Tx LED: Flashes when the device sends Modbus RTU packages
Rx LED: Flashes when the device receives Modbus RTU packages
System LED
Flashes during normal operation
Firmware Upgrade over Serial Line
Over the RS485 line; the running firmware is kept until the new image is checked (see the user manual)
POWER - DC
Input Range
9-48V DC wide range power input, polarity-independent
Reverse Polarity Protection
Available
Thermal Shutdown and Current Limit Protection
Available
PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS - DC POWERED MODELS
Enclosure
Metal, IP40
Dimensions
43 x 95 x 124 (w x d x h) mm
Weight
approx. 400 g
Storage Temperature
- 65 to 150 C
Operating Temperature
- 40 to 85 C
Operating Humidity
5% to 95% Non-condensing
HUR118: 8 Channel 5-275V AC/DC, 100mA Digital Optocoupler Output Modbus RTU Remote I/O Device, 1 x RS485, 9-48V DC Power Input