- 7 x 10/100Base-T(X) copper ports with auto MDI/MDIX plus one power line link (BPL)
- Ethernet over the power cables already in place: the network runs over the AC or DC power cables, no new cable is needed
- PN-AC version: 110 - 240 V AC three-phase supply; the units take their supply from L1 and neutral and carry the data phase to neutral, on any of the three phases
- 240 Mbps maximum PHY rate of the power line link; the data rate in use depends on the line and on the number of hops
- Wavelet OFDM in the 2 - 28 MHz band, 432 sub-carriers, LDPC-C error correction
- Encrypted: 128-bit AES link layer encryption on the power line
- Master or slave by a front panel switch; the units connect automatically, with no software; a network has only one master
- Two firmware options: direct links without relaying (up to 127 nodes per network) or multi-hop relaying (up to 10 hops and 1024 nodes)
- Quality of service in 16 levels, by MAC address, IEEE 802.1p or TCP port
- LEDs show the power line link, the activity and the master unit
- 110 - 240 V AC, 50 - 60 Hz power input on a three-phase line, supply from phase 1 and neutral; fuses on each line conductor and a varistor on the AC input
- Operating temperature -20 to +70 deg C
- Metal housing, Class II; DIN rail mounting
BPL (BROADBAND POWERLINE) TECHNOLOGY
PHY Rate
240 Mbps maximum PHY rate of the power line link; the data rate in use depends on the line and on the number of hops
Modulation
Wavelet OFDM in the 2 - 28 MHz band, 432 sub-carriers, LDPC-C error correction
Encryption
128-bit AES link layer encryption on the power line
Nodes and Hops
up to 127 nodes per network with the standard firmware (NoHop, direct links without relaying); up to 1024 nodes and 10 hops with the multi-hop firmware (Multi-Hop, the units relay for each other)
Quality of Service
16 levels, by MAC address, IEEE 802.1p or TCP port
Network
the units connect automatically; every network has one master, all other units are slaves
ETHERNET - BSB BPL
Ethernet Ports
7 x 10/100 Mbit/s copper ports with auto MDI/MDIX, plus one power line link (BPL)
Cable
10BASE-T: Cat. 3, 4 or 5, 100-ohm UTP; 100BASE-TX: Cat. 5, 100-ohm UTP; maximum length 100 m (328 ft)
RJ-45 Pins
pins 1, 2, 3 and 6 carry the data of 10BASE-T and 100BASE-TX; pins 4, 5, 7 and 8 are not used for data
CONNECTORS AND PORTS - BSB BPL
10/100T(X) RJ45 Ports
7 x RJ-45, 10/100 Mbit/s, with auto MDI/MDIX
Port LEDs
one link / activity LED for each port, in two rows of four and three
MASTER / SLAVE Switch
slide switch on the front panel with the two positions MASTER and SLAVE; set only one unit of a BPL network to MASTER
Power and Data Terminal
one 4-pin terminal block, 7.62 mm pitch, carries the power supply and the data connection
Terminal Pins
pin 1 neutral (N), no fuse, with L1 it supplies the unit; pin 2 phase 1 (L1), fused, with N it supplies the unit; pin 3 phase 2 (L2), fused; pin 4 phase 3 (L3), fused
Warning
mains voltage; installation by qualified personnel only; disconnect power before wiring
LED INDICATORS - BSB BPL
ACTIVITY
indicates the Ethernet connection of the unit: it shows the Ethernet link and flashes while the unit transmits or receives through Ethernet
LINK
shows that the connection with the remote unit over the power line is established
MASTER INDICATION
shows that the unit works as the master
POWER - BPL
Versions
AC powered version: 110 - 240 V AC, 50 - 60 Hz, three-phase line; the unit takes its supply from phase 1 (L1) and neutral (N). DC powered version: 9 - 36 V DC
Data Connection - Phase to phase (PP)
the data is carried phase to phase; phase to neutral is also possible. Available with AC and with DC power supply
Data Connection - Phase to neutral (PN)
the data is carried phase to neutral, on any of the three phases. Available with AC power supply
Data Connection - DC
the data is carried on the DC power line. Available with DC power supply
POWER - BSB BPL
Input Range
110 - 240 V AC, 50 - 60 Hz, on a three-phase line; the switch takes its supply from phase 1 and neutral
Power Consumption
max. 2.6 W (AC, measured)
Protection
fuses on each line conductor and a varistor on the AC input
Isolation
3 kV AC
Data Connection
phase to neutral, on any of the three phases: the units take their supply from L1 and neutral and carry the data phase to neutral
PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS - BSB BPL
Enclosure
Metal, Class II
Dimensions
44 x 95 x 125 mm (w x d x h)
Weight
460 g
Operating Temperature
-20 to +70 deg C
Storage Temperature
-40 to +85 deg C
Mounting
DIN rail
CONFORMITY - BSB BPL
EN IEC 62368-1 safety; EN 55032 Class B, EN 55035, EN 61000-3-2 and EN 61000-3-3 for CE; FCC Part 15 B Class B.
Tested by SGS in 2025 with three-phase AC supply: BSB612, BSB615 and BSB618.
BSB618-PN-AC: 7 x 10/100 + BPL, 110 - 240 V AC, Phase to neutral