TLM354 EU 868 MHz LoRaWAN EndNode Modem with Modbus TCP/RTU Scheduler, 2 x 10/100Base-T(X) Ports, 1 x RS232 and 1 x RS485 Serial Ports

TLM354
EU 868 MHz LoRaWAN EndNode Modem with Modbus TCP/RTU Scheduler, 2 x 10/100Base-T(X) Ports, 1 x RS232 and 1 x RS485 Serial Ports

per one
266.00 USD 280 USD
If you buy less than 5 items you will lose your 5% discount
-    Five device functions:
        - LoRaWAN to Modbus RTU Scheduler: reads up to 128 Modbus RTU query rows on the RS232 or RS485 port and sends the replies as LoRaWAN uplinks
        - LoRaWAN to Modbus TCP Scheduler: reads up to 128 Modbus TCP query rows (IP address and TCP port of each row) and sends the replies as LoRaWAN uplinks
        - LoRaWAN to TCP Server Gateway: TCP clients (up to 10) connect to the modem; their data goes to the LoRaWAN server as it is, downlinks go back to them
        - LoRaWAN to TCP Client Gateway: the modem connects to a remote TCP server and passes data between it and the LoRaWAN server
        - LoRaWAN to SERIAL Device Gateway: passes data between an RS232 or RS485 device (300 to 460800 baud) and the LoRaWAN server
-    Modbus scheduler rows: slave address, function code 01 to 04, data address, number of data, query interval, time out and LoRaWAN send interval for each row
-    Modbus RTU rows: RS232 or RS485 for each row, 9600 to 115200 baud with 8_NONE_1, 8_EVEN_1, 8_ODD_1 or 8_NONE_2; Modbus TCP rows: IP address and TCP port for each row, up to 10 TCP connections at the same time
-    Event uplink for each row: on a change or on a threshold with hysteresis (U16, S16, U32, S32 or Float32 value)
-    Error uplink for each row: a Modbus exception when there is no valid reply (code 0x0B; 0x0A when the TCP connection fails)
-    Time option for each row: the age of the reading (seconds) is added to the uplink
-    Downlink Modbus commands from the LoRaWAN server: function codes 1-2-3-4-5-6, 15 and 16
-    LoRaWAN band EU 868 MHz, frequency plan EU868 or EU868 with RX2 SF9
-    Activation over the air (OTAA) or by personalization (ABP); Class A or Class C; data transmission with or without ACK
-    Adaptive Data Rate, selectable uplink data rate and Tx power level (EIRP), LoRaWAN port 2 to 255
-    At most one uplink every 10 seconds; data larger than the maximum payload size is split into several uplinks; the duty cycle limit of the region applies
-    Device EUI read from the radio module and shown on the LoRa Settings page
-    Payload decoder for the network server in the user manual: a JavaScript function in the payload codec form used by The Things Network and ChirpStack
-    2 x 10/100Base-T(X) Ethernet ports, 1 x RS232 and 1 x RS485 serial ports
-    Embedded web interface; Device Status cards for LoRaWAN (with the age of the last uplink), LoRa Radio and the Device Function in use, plus a Serial card with the serial functions
-    DHCP client or static address; DHCP server; NTP time synchronization
-    White list and black list IP filter (TCP Server Gateway); password protected web interface
-    Firmware update over the web interface; two firmware banks in the device, the other firmware can be started again
-    Configuration backup and restore as a file
-    Log output to the console port, a UDP server or a syslog server (RFC 3164)
-    5 - 48 V DC power input (60 V maximum), protected against reverse polarity
-    Operating temperature -40 to 85 deg C
-    Rugged metal housing, IP 40
-    DIN rail mounting
LoRaWAN TECHNOLOGY - 868 MHz
Radio Band
EU 868 MHz
Frequency Plan
EU868 or EU868 with RX2 SF9; chosen with Band Selection on the LoRa Settings page (factory: "1: EUROPE 868MHz / Max. EIRP 16 dBm")
Uplink Data Rate
LoRa SF12 to SF7 / 125 kHz (250 to 5470 bps), or Adaptive Data Rate (factory: Adaptive Data Rate on; without it LoRa SF12 / 125 kHz / 250 bps)
Tx Power Level (EIRP)
0 to 16 dBm, configurable (factory 16 dBm)
Radio Module Output Power (conducted)
19.0 dBm typical
Sensitivity
down to -138 dBm
Link Budget
up to 156 dB
Communication Distance
up to 15 km line of sight
Sensitivity, link budget and distance are the values of the radio module datasheets.
Antenna
SMA female, 50 ohm
Activation
Over-the-Air (OTAA) or by Personalization (ABP)
LoRaWAN Class
Class A or Class C (factory Class C)
Transmission
without ACK or with ACK (factory without ACK)
LoRaWAN Port
2 to 255 for the data uplinks (factory 3); the status uplink always uses port 1
Device EUI
read from the radio module; Copy on the LoRa Settings page copies it for the network server


LoRaWAN UPLINK DETAILS - TLM
Every uplink starts with the 4-byte Device ID of the modem and one type byte: 0x00 status, 0x01 / 0x02 Modbus RTU / TCP reply, 0x03 / 0x04 transparent serial / TCP data, 0x05 / 0x06 Modbus reply with the row block (row number, cause and age of the reading).
After a join the modem sends a request for the network time, the status frame on port 1, then the data; a step that does not finish within its limit (5 tries / 180 s) is skipped, so data never waits behind it.
A reply longer than the maximum payload size of the current data rate is split into several uplinks; each part carries the frame header with its own data address and quantity.
When no uplink was sent for 12 hours, the modem sends its status frame again as keep-alive.
No restart on a JOIN timeout: the modem joins again in the background.
The byte layout of every frame, examples and the payload decoder are in chapters 11 - 13 of the user manual.


MODBUS SCHEDULER DETAILS - TLM
Rows
up to 128 query rows; a row is read only when Enable is ticked; the rows are read one after the other
Row Settings
slave address, function code (FC01 Coil Status, FC02 Input Status, FC03 Holding Reg., FC04 Input Reg.), data address, number of data, query interval, time out, uplink interval
Modbus RTU Rows
RS232 or RS485 for each row; 9600, 19200, 38400, 57600 or 115200 baud with 8_NONE_1, 8_EVEN_1, 8_ODD_1 or 8_NONE_2
Modbus TCP Rows
IP address and TCP port for each row; up to 10 TCP connections at the same time
Event Uplink
Change (an uplink also when the value changes by the set amount) or Threshold (an uplink when the value leaves or comes back into the band, with hysteresis); value type U16, S16, U32, S32 or Float32; needs FC03 or FC04; least time between event uplinks 10 to 65535 s (0 = 60 s)
Error Uplink
a Modbus exception uplink when the row gets no valid reply - 0x0B (gateway target device failed to respond), 0x0A (the Modbus TCP connection could not be made)
Time
adds the row number, the cause and the age of the reading (seconds) to every uplink of the row
Downlink Commands
function codes 01 to 06, 15 and 16; a complete Modbus RTU frame with CRC, or a Modbus TCP frame (MBAP header and PDU); the slave address must be the Slave Address of a row; the reply is sent back as an uplink
Status
Modbus Communication Status on the Device Status page - slave address, port or IP address, last query date, last Modbus package and the result of the last query


TRANSPARENT GATEWAY DETAILS - TLM
LoRaWAN to TCP Server Gateway
Server Listening Port, up to 10 TCP clients; white list or black list of 20 IP addresses each
LoRaWAN to TCP Client Gateway
Server Static IP Address and LoRa Server Listening Port of the remote TCP server
LoRaWAN to SERIAL Device Gateway
RS232 or RS485, baud rate 300 to 460800 and line control
The data goes to the LoRaWAN network server as it is, and downlinks go back to the TCP clients, the TCP server or the serial port.


ETHERNET TECHNOLOGY
Ethernet Standards 
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X)
IEEE 802.3x Flow Control
Mac Table 
1K MAC address entry
Processing 
Store-and-Forward
Memory 
448K bits packet buffer memory


NETWORK AND MANAGEMENT - TLM
Address
DHCP client or static address; without a DHCP server the modem continues on 192.168.1.1 / 255.255.255.0 after 60 s; DHCP server for the devices on its Ethernet ports
Network Watchdog
the modem checks its network gateway every 60 s; after 5 failures in a row it renews its DHCP lease, after 10 it asks for a new address, after 15 it restarts (in the serial functions a network loss never restarts the modem)
Time
NTP time server set on the Network Settings page; Set Device Time on the Management page writes the PC time as UTC
Firmware
Live Firmware Update on the Management page writes the new firmware into the other bank; Reboot Alternative Firmware starts it; the firmware that ran before stays in the other bank; a firmware of another frequency band is refused at the bank switch
Configuration File
all settings saved as a file and loaded back; the file holds the LoRaWAN keys; a file is loaded only into a modem of the same product and variant
Log Output
CONSOLE, UDP SERVER or SYSLOG (RFC 3164, program name TLM_LW); Log Level NONE, ERROR, INFO or DEBUG (factory NONE)
Web Interface
user admin, password admin from the factory - change it after the first login


CONNECTORS AND PORTS - TLM
SMA Antenna Connector
standard SMA female antenna interface, 50 ohm
Console Port
Micro USB or USB Type-C, log output, 115200 baud; a new modem prints nothing (Log Level NONE from the factory)
10/100T(X) RJ45 Ports
2 x 10/100Base-T(X) Ethernet ports
Serial Ports
5 pin terminal block - RS232 Tx, Rx and GND; RS485 A, B and GND
Reset Buttons
RESET TO SERVER and RESET TO CLIENT, held for more than 5 seconds: factory settings (LoRaWAN keys included) with the Device Function LoRaWAN to TCP Server Gateway or LoRaWAN to TCP Client Gateway, then a restart


LED INDICATORS
Power
on when the modem has power
STATUS
blinks while the modem waits for its network or connection; stays on while it serves its Device Function
Tx / Rx
blink when the modem sends or receives data
SERVER
on with LoRaWAN to TCP Server Gateway, LoRaWAN to SERIAL Device Gateway and LoRaWAN to Modbus RTU Scheduler; off with LoRaWAN to TCP Client Gateway and LoRaWAN to Modbus TCP Scheduler
Ethernet
activity LEDs for port 1, port 2 and the modem itself; they blink with Ethernet traffic
Console
Tx and Rx blink when data is sent or received


POWER
Input Range
5 - 48 V DC (60 V maximum)
Protection
reverse polarity, so the input can be connected either way round; thermal shutdown and current limit


PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
Enclosure
Metal, IP 40
Dimensions
43 x 95 x 124 mm (w x d x h)
Weight
approx. 400 g
Operating Temperature
-40 to 85 deg C
Storage Temperature
-65 to 150 deg C
Operating Humidity
5 to 95 %, non-condensing
Mounting
DIN rail


TLM354: 868 MHz LoRaWAN EndNode Modem, 2 x 10/100Base-T(X) Ethernet ports, 1 x RS232 and 1 x RS485, 5 - 48 V DC power input (60 V maximum)
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
TLM Series LoRa Modems and LoRaWAN EndNode Modems
TLM Series LoRa Modems and LoRaWAN EndNode Modems
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
HUR Series Modbus TCP and RTU Remote I/O Devices with MQTT (and LoRaWAN)
HUR Series Modbus TCP and RTU Remote I/O Devices with MQTT (and LoRaWAN)
BKV Series Industrial Converters and USB Tools
BKV Series Industrial Converters and USB Tools
MBC Series IEC62056-21 Protocol Auto Baud Changer
MBC Series IEC62056-21 Protocol Auto Baud Changer
KMK Series Optical Probes for Energy Meters
KMK Series Optical Probes for Energy Meters
REDZ Software Solutions
REDZ Software Solutions
LoRaWAN
LoRaWAN
In today's rapidly digitizing world, IoT (Internet of Things) devices and applications are becoming increasingly prevalent. In this context, long-range wireless communication technologies play a significant role. One such technology that stands out is LoRa, which offers an innovative solution for low-power, long-range wireless communication.
MQTT
MQTT
As the Internet of Things (IoT) continues to grow, the demand for efficient, lightweight, and reliable communication protocols becomes essential. One of the most popular protocols meeting these demands is MQTT (Message Queuing Telemetry Transport).
Broadband Power Line (BPL)
Broadband Power Line (BPL)
Broadband Powerline Technology (BPL), also known as Powerline Communication (PLC), represents a revolutionary approach to data transmission, leveraging the existing electrical power infrastructure to deliver broadband internet connectivity.
Wireless MBus (WMBus)
Wireless MBus (WMBus)
In an era defined by connectivity and data-driven decision-making, the need for efficient and reliable metering solutions has never been greater. Enter Wireless M-Bus (Meter-Bus) technology, a versatile and robust platform designed to revolutionize remote meter reading and data communication in utility management systems.
IEC62056-21 (for Electricity Meters)
IEC62056-21 (for Electricity Meters)
IEC 62056-21 is an international standard for communication with electricity meters. Developed by the International Electrotechnical Commission (IEC), this protocol standardizes the way data is exchanged between meters and various devices or systems, ensuring interoperability and efficient data management.
DLMS/COSEM (for Electricity Meters)
DLMS/COSEM (for Electricity Meters)
DLMS/COSEM (Device Language Message Specification / Companion Specification for Energy Metering) is the global standard for smart energy metering. It provides a highly secure, interoperable framework for reading and managing energy data across diverse utility networks.
P1 Companion Standard (for Electricity Meters)
P1 Companion Standard (for Electricity Meters)
Smart energy meters have become essential in monitoring and controlling energy usage. To facilitate better integration, communication, and functionality of these smart meters, standards are crucial. One such standard, particularly relevant in Europe, is the P1 Companion Standard.
Modbus RTU
Modbus RTU
Modbus RTU is a widely recognized and utilized communication protocol in the field of industrial automation. Developed by Modicon (now Schneider Electric) in 1979, it was designed to facilitate communication between various electronic devices, primarily programmable logic controllers (PLCs).
Modbus TCP
Modbus TCP
Modbus TCP, also known as Modbus TCP/IP, is a widely adopted communication protocol in the industrial automation sector. It was developed to enable Modbus communication over Ethernet networks, combining the reliability and simplicity of the Modbus protocol with the versatility of Ethernet.
LoRa RF Communication
LoRa RF Communication
LoRa stands for Long Range and is a proprietary wireless modulation technique developed by Semtech. Essentially, LoRa is the physical layer, or the hardware, that allows long-range communication between devices.
MBus
MBus
M-Bus (Meter-Bus) is a robust European standard specifically designed for the remote reading of utility meters, such as electricity, gas, water, and heat. It utilizes a simple, polarity-independent two-wire system that transmits both data and power over long distances, making it highly cost-effective and immune to industrial noise.