We use cookies to optimize site functionality and provide the best possible experience.
View our new Privacy and Protection of Personal Data here.
Accept Settings
865MHz LoRaWAN EndNode Modem with Modbus TCP/RTU Scheduler with 2 x 10/100Base-T(x) Ports, 1 x RS232 and 1 x RS485 Serial Ports
TLM344
865MHz LoRaWAN EndNode Modem with Modbus TCP/RTU Scheduler with 2 x 10/100Base-T(x) Ports, 1 x RS232 and 1 x RS485 Serial Ports
per one
266.00 USD 280 USD
If you buy less than 5 items you will lose your 5% discount
-    5-48V (max. 60V) DC wide range power input
-    Supports 2 x 10/100Base-T(X) ports
-    Supports Full/Half-Duplex, auto MDI/MDI-X on each port
-    Supports 1 x RS232 and 1 x RS485 Serial Connection up to 460800 Baud
-    Embedded web interface for ease of use
-    Radio Band Options:
865MHz
IN 865 MHz – India, LoRaWAN RF Communication
-    3 Main Device Functions:
LoRaWAN Modbus TCP Scheduler
LoRaWAN Modbus RTU Scheduler
LoRaWAN Transparent Mode (Transparent bridge between LoRaWAN and TCP/IP or Serial Side)
-    Up to 40 device connection in Modbus TCP or RTU Scheduler modes 
-    Up to 10 device connection in Transparent TCP/IP mode 
-    Definable Modbus Serial Interface for Modbus RTU (RS232 or RS485 usage in same device)
-    Selectable Modbus Function Code, Definable Register Address, Total Register Number, Query Interval and Time Out durations.
-    Built in LoRaWAN payload size check. User can read any data in any interval
-    TLM will automatically split based on Maximum Payload Size allowed
-    Activation Over Air (OTAA) or Activation by Personalization (ABP) Selectable
-    User defined LoRAWAN Port
-    Adaptive Data Rate functionality
-    Selectable Uplink Data Rate
-    Selectable Power Level
-    LoRaWAN Class C and Class A support
-    Easy monitor of transmitted data on web interface
-    Easy to follow Device Status on web interface
-    Easy to follow LoRaWAN packages on web interface 
-    Black List and White List based TCP/IP connection filter in transparent mode
-    Firmware Upgrade over Web
-    2 firmware storage capability on same device (1 active only)
-    Wide operating temperature range from -40 to 85 °C
-    Rugged Metal IP-40 housing design
-    DIN-Rail mounting
TECHNOLOGY
LoRa TECHNOLOGY

Based on 
STM32L151CxU6Axx
Pre-Certified according to EN 300 220
Sensitivity 
Down to -138 dBm
Link Budget 
Up to 156 dB
Communication Distance 
Up to 15km (Line of Sight)
Typical Communication Distance Indoor/Urban
>2km
LoRaWAN Activation Options 
Activation Over Air (OTAA)
Activation by Personalization (ABP)
User Selectable
LoRaWAN Port
User Selectable
Adaptive Data Rate
Available
Uplink Data Rate 
SF12 / 125 kHz / 250 bps
SF11 / 125 kHz / 440 bps
SF10 / 125 kHz / 980 bps
SF9 / 125 kHz / 1760 bps
SF8 / 125 kHz / 3125 bps
SF7 / 125 kHz / 5470 bps
FSK 50k / NA / 50000 bps
Tx Power Level 
0 to 22dBm Configurable
LoraWAN Class 
Class A
Class C

ETHERNET SWITCH TECHNOLOGY

Ethernet Standards 
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X)
IEEE 802.3x Flow Control
Mac Table 
1K MAC address entry
Processing 
Store-and-Forward
Memory 
448K bits packet buffer memory


MODBUS CHARACTERISTICS
Modbus Protocol
Modbus TCP or RTU
Selectable by User
Modbus Devices
Up to 40 Modbus command can be defined by User
Modbus Address
Independently selectable by User
Modbus Function Code
Read Coil Status (FC=01)
Read Input Status (FC=02)
Read Holding Registers (FC=03)
Read Input Registers (FC=04)
Selectable
Modbus Command Setting
Register Adress
Total Number of Registers
Query Interval
Time Out 
Independently Selectable for each command
Modbus RTU Serial Settings
Serial interface RS232 or RS485
Serial data settings and Baud Rate
Independently Selectable for each command


CONNECTORS AND PORTS
SMA Antenna Connector for LoRa

1 Standard SMA female interface, 50 ohm

Console Port
USB Type-C or Micro USB connection for LOG in 115200 baud
10/100T(X) RJ45 Ports
Ethernet Connection on 2 ports
Serial Ports
5 pin wired Terminal Connection
Tx, Rx, GND for RS232
A, B and GND for RS485
Reset Buttons
Reset to Client and Reset to Server Operating modes buttons



LED INDICATORS
Power indicator
Power LED
10/100T(X) Indicators
Activity LEDs:
ETH1, ETH2 and TLM (Activity of device itself)
System Indicators
Status LED,
Tx and Rx of data LEDs and Server LED
(LED ON: Server Operating Mode, LED OFF: Client Operating Mode)
Console Indicators
Tx and Rx of data LEDs


POWER
Input Range

5-48V DC wide range power input

(Allows up to 60 V DC)
Reverse Polarity Protection
Available
Thermal Shutdown and Current Limit Protection
Available


PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
Enclosure
Metal, IP 40
Dimensions
43 x 95 x 124 (w x d x h) mm
Weight
~400gr
Storage Temperature
-65 to 150 °C
Operating Temperature
-40 to 85 °C 
Operating Humidity
5% to 95%Non-condensing


TLM344: 865MHz LoRaWAN EndNode Modem with Modbus TCP/RTU Scheduler, 2x 10/100 T(x) ETH ports, 1 x RS232 & 1 x RS485, 5-48V (max. 60V) DC Power Input
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
TLM Series LoRa Modems and LoRaWAN EndNode Modems
TLM Series LoRa Modems and LoRaWAN EndNode Modems
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
KMK Series Optical Probes for Energy Meters
HUR Series Modbus TCP and RTU Remote I/O Devices with MQTT (and LoRaWAN)
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
MBC Series IEC62056-21 Protocol Auto Baud Changer
KMK Series Optical Probes for Energy Meters
REDZ Software Solutions
LoRaWAN
LoRaWAN
In today's rapidly digitizing world, IoT (Internet of Things) devices and applications are becoming increasingly prevalent. In this context, long-range wireless communication technologies play a significant role. One such technology that stands out is LoRa, which offers an innovative solution for low-power, long-range wireless communication.
MQTT
MQTT
As the Internet of Things (IoT) continues to grow, the demand for efficient, lightweight, and reliable communication protocols becomes essential. One of the most popular protocols meeting these demands is MQTT (Message Queuing Telemetry Transport).
Broadband Power Line (BPL)
Broadband Power Line (BPL)
Broadband Powerline Technology (BPL), also known as Powerline Communication (PLC), represents a revolutionary approach to data transmission, leveraging the existing electrical power infrastructure to deliver broadband internet connectivity.
Wireless MBus (WMBus)
Wireless MBus (WMBus)
In an era defined by connectivity and data-driven decision-making, the need for efficient and reliable metering solutions has never been greater. Enter Wireless M-Bus (Meter-Bus) technology, a versatile and robust platform designed to revolutionize remote meter reading and data communication in utility management systems.
IEC62056-21 (for Electricity Meters)
IEC62056-21 (for Electricity Meters)
IEC 62056-21 is an international standard for communication with electricity meters. Developed by the International Electrotechnical Commission (IEC), this protocol standardizes the way data is exchanged between meters and various devices or systems, ensuring interoperability and efficient data management.
P1 Companion Standard (for Electricity Meters)
P1 Companion Standard (for Electricity Meters)
Smart energy meters have become essential in monitoring and controlling energy usage. To facilitate better integration, communication, and functionality of these smart meters, standards are crucial. One such standard, particularly relevant in Europe, is the P1 Companion Standard.
Modbus RTU
Modbus RTU
Modbus RTU is a widely recognized and utilized communication protocol in the field of industrial automation. Developed by Modicon (now Schneider Electric) in 1979, it was designed to facilitate communication between various electronic devices, primarily programmable logic controllers (PLCs).
Modbus TCP
Modbus TCP
Modbus TCP, also known as Modbus TCP/IP, is a widely adopted communication protocol in the industrial automation sector. It was developed to enable Modbus communication over Ethernet networks, combining the reliability and simplicity of the Modbus protocol with the versatility of Ethernet.
LoRa RF Communication
LoRa RF Communication
LoRa stands for Long Range and is a proprietary wireless modulation technique developed by Semtech. Essentially, LoRa is the physical layer, or the hardware, that allows long-range communication between devices.