We use cookies to optimize site functionality and provide the best possible experience.
View our new Privacy and Protection of Personal Data here.
Accept Settings
MODBUS RTU to IEC62056-21 Protocol Meter Gateway With RS485 2 Wire Connection on Both Modem Side and Meter Side
LKM144
MODBUS RTU to IEC62056-21 Protocol Meter Gateway With RS485 2 Wire Connection on Both Modem Side and Meter Side
per one
199.50 USD 210 USD
If you buy less than 5 items you will lose your 5% discount
-    4 Slots x 5 Channel 4-20mA Analog Output
-    Supports 2 x 10/100Base-T(X) ports
-    Embedded web interface for ease of use
-    Radio Band Options:
868MHz
EU 868 MHz – Europe, LoRaWAN RF Communication
-    LoRaWAN data send interval configurable
-    MQTT Publisher with different data transfer options

      Parsed Data as Data Objects
      Parsed Data as Modbus Frame

-    HUR can send Data to Server and MQTT Server can remotely control Output Versions of HUR Devices in the same time
-    Logic Function commands available to make field automation based on I/O status
-    Built in LoRaWAN Duty Cycle Check
-    Activation Over Air (OTAA) or Activation by Personalization (ABP) Selectable
-    User defined LoRAWAN Port
-    Adaptive Data Rate functionality
-    Selectable Uplink Data Rate
-    Selectable Power Level
-    LoRaWAN Class C and Class A support
-    Easy to follow Device Status on web interface
-    Easy to follow LoRaWAN packages on web interface 
-    Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
-    Easy to follow Modbus data packages on web interface 
-    Up to 10 client connection in Server Mode
-    DHCP Server Capability
-    Device Address changeable via web interface
-    Output configuration can be defined by user for restart 
-    Output values can be saved and applied during auto restart
-    I/O Mirror functionality: Device can duplicate output from a Modbus input device
-    Black List and White List based IP Filter in TCP Server Mode
-    Firmware Upgrade over Web
-    2 firmware storage capability on same device (1 active only)
-    100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC wide range power input
-    Wide operating temperature range from -25 to 70 °C
-    Rugged Metal IP-40 housing design
-    DIN-Rail mounting
LoRaWAN TECHNOLOGY
Based on 
STM32L151CxU6Axx
Pre-Certified according to EN 300 220
Sensitivity 
Down to -138 dBm
Link Budget 
Up to 156 dB
Communication Distance 
Up to 15km (Line of Sight)
Typical Communication Distance Indoor/Urban
>2km
LoRaWAN Activation Options 
Activation Over Air (OTAA)
Activation by Personalization (ABP)
User Selectable
LoRaWAN Port
User Selectable
Adaptive Data Rate
Available
Uplink Data Rate 
SF12 / 125 kHz / 250 bps
SF11 / 125 kHz / 440 bps
SF10 / 125 kHz / 980 bps
SF9 / 125 kHz / 1760 bps
SF8 / 125 kHz / 3125 bps
SF7 / 125 kHz / 5470 bps
SF7 / 250 kHz / 11000 bps
FSK 50k / NA / 50000 bps
Tx Power Level 
0 to 16dBm Configurable
LoraWAN Class 
Class A
Class C
LoraWAN Data Send
Interval defined by user
Data Format as Modbus Frame


ETHERNET TECHNOLOGY
Ethernet Standards 
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X)
IEEE 802.3x Flow Control
Mac Table 
1K MAC address entry
Processing 
Store-and-Forward
Memory 
448K bits packet buffer memory


LoRaWAN DETAILS
Status Message - Device Status
Message sent to LoRaWAN Port number 1 in every connection to LoRaWAN Server
4 Bytes: HUR Device Id
1 Byte: Frame Type (Lower 4 bits) and Package Number (Upper 4 bits). If Package Number is 1 or more that means the package splitted.
0x00 : means status package for device status and package is the first package
1 Byte: Number of I/O Slots available in HUR device
1 Byte for each Slot (4 bytes for 4 Slots): Slot Types available in HUR device
Available Options: 'HUR_8_DIGITAL_IN', 'HUR_8_DIGITAL_OUT', 'HUR_8_ANALOG_IN', 'HUR_5_ANALOG_OUT'
1 Byte: LoRaWAN target port for I/O data
4 Bytes: RTC Time
3 Bytes: HUR Device firmware version
N Bytes (maximum 22): LKM Device name configured by userI/O Data Message
Message sent to LoRaWAN configured port and minimum send interval can be configured by user
4 Bytes: HUR Device Id
1 Byte: Frame Type (Lower 4 bits) and Package Number (Upper 4 bits). If Package Number is 1 or more that means the package splitted.
0x02 : means meter data package and package is the first package
4 Bytes: RTC Time
1 Byte: Number of I/O Slot which the data is shared
1 Byte: Type of I/O Slot which the data is shared
1 Byte: Total number of bytes in Payload
1 Byte For 'HUR_8_DIGITAL_IN' and 'HUR_8_DIGITAL_OUT' Slots
16 Bytes for 'HUR_8_ANALOG_IN' Slots
10 Bytes for 'HUR_5_ANALOG_OUT' Slots


MODBUS DETAILS - OUTPUT MODELS
Protocol
Modbus TCP
Modbus Address
Default value is 0x01
Changeable via Web Interface
Save Output Values Before Auto Restart
Default enabled and when system auto restarts the values are saved and applied after restart
Save Output Values and Apply on Power Up
Default disabled, user can activate and enter parameters for each output individually
Changeable via Web Interface
I/O Mirror Functionality
Default disabled
If enabled, device can read input value of remote HUR device and duplicate those values as output
Monitoring Parameters
Modbus Read counter
Time counter (in seconds)
FW version
Device Up Time
TCP packages


MQTT DETAILS
MQTT Publisher can be enabled and can be used in parallel with Modbus conversion (or stand alone)
MQTT Connection
Broker IP and Port can be entered
Client ID , User name and Password can be set
Publish Topic and Subscribe Topic can be defined from web interface
Data Send Interval
User can send Data send interval in seconds
Default is 60 seconds and HUR will send meter data to MQTT server in that interval

NTP Server
NTP server time will be added to each MQTT message

Data Format
There are 2 predefined formats
Parsed Data As Objects: Sends I/O values in ASCII readable fromat
Parsed Data as Modbus Frame: Send just like the response of Modbus query as hex data (smaller data size)


I/O LOGIC FUNCTIONS
All versions of HUR Series Modbus TCP Remote Input/Output (I/O) Devices support I/O Logic Functions which can be used to make field automation by using HUR Series itself in the field. As an example, device can be programmed to Turn ON Output or send status of input values to MQTT server or LoRaWAN Server when an input dedected. There are many combinations available.
I/O Logic Commands
16 commands available in Multi Slot Models
8 commands available in Single Slot Models
Condition Slot and I/O
HUR can check programmed input or output of selected slot. This can be any of the available slot (Analog Input, Digital Input, Analog Output or Digital Output)
Condition Command
For Analog Input and Analog Output: HUR can check if the selected I/O value is Higher or Lower than user specified value
For Digital Input and Digital Output: HUR can check if the selected I/O value is ON, OFF or its State Changed (from ON to OFF or OFF to ON)
Condition Duration
HUR can check the command for user defined duration and function is only triggered when command is true for specified duration 
Result Slot and I/O
This is the affected input or output number of slot for triggered command. This can be any of the available slot (Analog Input, Digital Input, Analog Output or Digital Output)
Result Command
For Digital Output and Analog Output: HUR can set output to specific value. It can be On, Off or State Change for Digital Output model and can be user defined value for Analog Output Model
For All Slot Models: HUR can send MQTT message or LoRaWAN message for specified slot when command is triggered

Wait Before Next Check

Once the command is triggered, HUR can wait for next check of command based on user defined duration
Examples

Examples applies to models with the mentioned hardware
HUR can send MQTT message for selected slot if an Analog Input Value is Higher than 10mA.
HUR can send LoRaWAN message for selected slot if an Analog Input Value is Lower than 10mA.
HUR can set Output On for selected Digital Output slot if a Digital Input value is OFF


CONNECTORS AND PORTS - LoRa
SMA Antenna Connector for LoRa

1 Standard SMA female interface, 50 ohm

Console Port
USB Type C or Micro USB connection for LOG in 115200 baud
10/100T(X) RJ45 Ports
Ethernet Connection on 2 ports
Reset Buttons
Reset to Client and Reset to Server Operating modes buttons


I/O TERMINAL - 4 Slots x 5 Channel Analog Output
I/O Connectors
Terminal Connectors
Analog Outputs: 4 Slots x 5 Channel 4-20mA Analog Output
5 Analog Outputs total 10 connection pins for each slot.
4-20mA Analog Output designed for 24V 250ohm load or 12V 125ohm load.
Over Voltage Protection
Analog Output:
40V


LED INDICATORS - MULTI SLOT
Power Indicator
Power LED
10/100T(X) Indicators
Activity LEDs:
ETH1, ETH2 and HUR (Activity of device itself)
System Indicators
Status LED,
Tx and Rx of data LEDs and Server LED
(LED ON: Server Operating Mode, LED OFF: Client Operating Mode)
Slot LEDs

S-1, S-2, S-3 and S-4: Turns On for 1 second and Turns OFF for 1 second under normal operation of I/O Interface.
Each LED corresponds to related I/O Slot.
Console Indicators

Tx and Rx of data LEDs


POWER - AC
Input Range
100 - 240V AC (120 – 370V DC), 50Hz to 60Hz Wide Range AC Power Input
Isolation
Fully Isolated >4200Vrms, 5mA 1 Min
Insulation
Class II


PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS - MULTI SLOT - AC POWERED MODELS
Enclosure
Metal, IP 40
Dimensions
115 x 970 x 126 (w x d x h) mm
Weight
~700gr
Storage Temperature
-40 to 105 °C
Operating Temperature
-25 to 70 °C
Operating Humidity
5% to 95% Non-condensing


LKM144: Modem side RS485, Meter side RS485, Modbus RTU to IEC 62056-21 Protocol Meter gateway
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways with MQTT (and LoRaWAN)
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
STG Series WMBus (Wireless MBus) - Modbus Protocol Gateway with MQTT
TLM Series LoRa Modems and LoRaWAN EndNode Modems
TLM Series LoRa Modems and LoRaWAN EndNode Modems
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
CKL Series Modbus TCP and RTU Gateways and Serial to Ethernet Gateways
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
BSB Series Industrial Unmanaged Ethernet Switch (with Broadband Power Line)
KMK Series Optical Probes for Energy Meters
HUR Series Modbus TCP and RTU Remote I/O Devices with MQTT (and LoRaWAN)
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
BKV Series USB Tools, RS232/485 Converters, Ethernet Switches, USB 2.0 Hubs, 868MHZ WMBus Converters, P1 Meter Converters
MBC Series IEC62056-21 Protocol Auto Baud Changer
KMK Series Optical Probes for Energy Meters
REDZ Software Solutions
LoRaWAN
LoRaWAN
In today's rapidly digitizing world, IoT (Internet of Things) devices and applications are becoming increasingly prevalent. In this context, long-range wireless communication technologies play a significant role. One such technology that stands out is LoRa, which offers an innovative solution for low-power, long-range wireless communication.
MQTT
MQTT
As the Internet of Things (IoT) continues to grow, the demand for efficient, lightweight, and reliable communication protocols becomes essential. One of the most popular protocols meeting these demands is MQTT (Message Queuing Telemetry Transport).
Broadband Power Line (BPL)
Broadband Power Line (BPL)
Broadband Powerline Technology (BPL), also known as Powerline Communication (PLC), represents a revolutionary approach to data transmission, leveraging the existing electrical power infrastructure to deliver broadband internet connectivity.
Wireless MBus (WMBus)
Wireless MBus (WMBus)
In an era defined by connectivity and data-driven decision-making, the need for efficient and reliable metering solutions has never been greater. Enter Wireless M-Bus (Meter-Bus) technology, a versatile and robust platform designed to revolutionize remote meter reading and data communication in utility management systems.
IEC62056-21 (for Electricity Meters)
IEC62056-21 (for Electricity Meters)
IEC 62056-21 is an international standard for communication with electricity meters. Developed by the International Electrotechnical Commission (IEC), this protocol standardizes the way data is exchanged between meters and various devices or systems, ensuring interoperability and efficient data management.
P1 Companion Standard (for Electricity Meters)
P1 Companion Standard (for Electricity Meters)
Smart energy meters have become essential in monitoring and controlling energy usage. To facilitate better integration, communication, and functionality of these smart meters, standards are crucial. One such standard, particularly relevant in Europe, is the P1 Companion Standard.
Modbus RTU
Modbus RTU
Modbus RTU is a widely recognized and utilized communication protocol in the field of industrial automation. Developed by Modicon (now Schneider Electric) in 1979, it was designed to facilitate communication between various electronic devices, primarily programmable logic controllers (PLCs).
Modbus TCP
Modbus TCP
Modbus TCP, also known as Modbus TCP/IP, is a widely adopted communication protocol in the industrial automation sector. It was developed to enable Modbus communication over Ethernet networks, combining the reliability and simplicity of the Modbus protocol with the versatility of Ethernet.
LoRa RF Communication
LoRa RF Communication
LoRa stands for Long Range and is a proprietary wireless modulation technique developed by Semtech. Essentially, LoRa is the physical layer, or the hardware, that allows long-range communication between devices.