LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM Series Electricity Meter to Modbus Protocol Gateways are designed to be used with electricity meters that communicates in IEC62056-21 or P1 Companion Standard. The meters that supports IEC62056-21 and P1 Companion Standard has read out tables that has several data such as import energy, export energy, phase voltages and currents. LKM Series Electricity Meter to Modbus Protocol Gateways automatically reads that values and maps to Modbus registers.
Field devices or software systems can easily read data over Modbus RTU or Modbus TCP protocol based on device model so that energy meter reading can easily be integrated to field automation systems without need of IEC6056-21 protocol or P1 Companion Standard implementation.
Product Filter reset


LKM154 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM154 -    5-48V DC wide range Power Input (allows up to 60V DC)
-    Supports 2 x 10/100Base-T(X) ports
-    Supports 1 x RS232 and 1 x RS485 Serial Connection up to 115200 Baud
-    2 Different Gateway Operating Modes:     
     Serial IEC Meter to Modbus TCP Gateway with MQTT Publisher
     TCP/IP IEC Meter to Modbus RTU Gateway with MQTT Publisher
-    Up to 20 IEC Meter reading and conversion of their data to Modbus TCP or RTU
-    Reading Up to 48 OBIS Registers. All configurable from web interface 

-    MQTT Publisher with different data tansfer options
     OBIS Values as Data Objects
     OBIS Values as Modbus Frame
280 USD
Learn more
LKM254 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM254 Covers all features of TLM154

Difference:

-    100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC wide range power input
-    Wide operating temperature range from -25 to 70 °C 
290 USD
Learn more
LKM655 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM655 Covers all features of LKM154


Differences:
- Supports 2 x 10/100Base-T(X) ports + 1 x BPL link
- Wide Range 3 phase input, 110V–240V/50-60Hz wide range Power Input
- Supports up to 30Mbps PHY rate on BPL with Up to 10 hops and 1000 nodes
- Up to 432 sub-carriers from 2 to 28MHz analog bandwidth on BPL
370 USD
Learn more
LKM354 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM354 -    5-48V (max. 60V) DC wide range power input
-    Supports 2 x 10/100Base-T(X) ports
-    Supports 1 x RS232 and 1 x RS485 Serial Connection up to 115200 Baud
-    Radio Band Options:
868MHz
EU 868 MHz – Europe, LoRaWAN RF Communication
-    LoRaWAN data send interval configurable
-    2 Different Gateway Operating Modes:     
     Serial IEC Meter to LoRaWAN Gateway with MQTT Publisher
     TCP/IP IEC Meter to LoRaWAN Gateway with MQTT Publisher
-    Up to 20 IEC Meter reading and conversion of their data to Modbus TCP or RTU
-    Reading Up to 48 OBIS Registers. All configurable from web interface
-    MQTT Publisher with different data tansfer options
     OBIS Values as Data Objects
     OBIS Values as Modbus Frame
-    Built in LoRaWAN Duty Cycle Check
-    Built in LoRaWAN payload size check. User can read data in any interval
     LKM will automatically split based on Maximum Payload Size allowed and Duty Cycle Block Times
-    Activation Over Air (OTAA) or Activation by Personalization (ABP) Selectable
-    User defined LoRAWAN Port
-    Selectable Uplink Data Rate
-    Selectable Power Level
-    LoRaWAN Class C and Class A support

340 USD
Learn more
LKM454 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM454 Covers all features of LKM354


Difference:
-    100 - 240V AC (120 – 370V DC), 50Hz to 60Hz AC wide range power input
-    Wide operating temperature range from -25 to 70 °C 
350 USD
Learn more
LKM755 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM755 Covers all features of LKM354


Differences:
- Supports 2 x 10/100Base-T(X) ports + 1 x BPL link
- Wide Range 3 phase input, 110V–240V/50-60Hz wide range Power Input
- Supports up to 30Mbps PHY rate on BPL with Up to 10 hops and 1000 nodes
- Up to 432 sub-carriers from 2 to 28MHz analog bandwidth on BPL
420 USD
Learn more
LKM111 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM111 -    RS232, 3 Wire (Tx-Rx-GND) Connection on Modem Side and Meter Side
-    Auto reads Electricity meters that communicates in IEC62056-21 standard and maps in predefined MODBUS register table
-    Configurable Modbus address via Modbus Commands 
-    Configurable Reading Period on IEC6056-21 side via Modbus Commands
-    Configurable Reading Table Number on IEC6056-21 side via Modbus Commands 
-    Wide range power input: 5V – 24V DC
-    Wide operating temperature range from -40 to 85 °C 
-    Very Small form factor, only 2.1 x 4.2 x 4.4cm
-    Customization of reading process and register tables based on client request
-    Firmware upgradable over serial line
210 USD
Learn more
LKM114 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM114 Covers all features of LKM111


Difference:
-    RS485 2 Wire Connection on Modem Side and RS232 3 Wire Connection on Meter Side
210 USD
Learn more
LKM124 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM124 Covers all features of LKM111


Difference:
-    RS485 2 Wire Connection on Modem Side and P1 Interface on Meter Side
210 USD
Learn more
LKM141 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM141 Covers all features of LKM111



Difference:
-    RS232 DB9 Male on Modem Side and RS485 2 Wire Connection on Meter Side

210 USD
Learn more
LKM144 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM144 Covers all features of LKM111


Difference:
-    RS485 2 Wire Connection on Both Modem Side and Meter Side
210 USD
Learn more
LKM614 LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM614 -   Especially plug and play designed for EMH LXQJ-XC meters
-   Direct replacement for Variomod XC modules for EMH meters
-   Auto reads EMH meters and maps values in predefined MODBUS register table
-   Configurable Modbus address via Modbus Commands 
-   Configurable Reading Period on IEC6056-21 side via Modbus Commands
-   Configurable Reading Table Number on IEC6056-21 side via Modbus Commands 
-   Gets power directly from meter
-   Serial interface directly connected to meter ( with 15kV ESD protection)
-   Wide operating temperature range from -40 to 85 °C 
-   Customization of reading process and register tables based on client request
-   Firmware upgradable over serial line
225 USD
Learn more
BSB Series Industrial Unmanaged Ethernet Switch
BSB Series Industrial Unmanaged Ethernet Switch
TLM Series LoRa and LoRaWAN Modems
TLM Series LoRa and LoRaWAN Modems
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
CKL Series Modbus, Serial to Ethernet Gateway
CKL Series Modbus, Serial to Ethernet Gateway
STG Series WMBus (Wireless MBus) - Modbus TCP/RTU Gateway
STG Series WMBus (Wireless MBus) - Modbus TCP/RTU Gateway
HUR Series Modbus TCP and RTU Remote I/O Devices
HUR Series Modbus TCP and RTU Remote I/O Devices
MBC Series IEC62056-21 Protocol Auto Baud Changer
MBC Series IEC62056-21 Protocol Auto Baud Changer
KMK Series Optical Probes for Energy Meters
REDZ Software Solutions