MODBUS RTU to IEC62056-21 Protocol Meter Gateway for EMH LZQJ-XC Meters With RS485 2 Wire Connection on Modem Side
LKM614
MODBUS RTU to IEC62056-21 Protocol Meter Gateway for EMH LZQJ-XC Meters With RS485 2 Wire Connection on Modem Side
per one
213.75 USD 225 USD
If you buy less than 5 items you will lose your 5% discount
-   Especially plug and play designed for EMH LXQJ-XC meters
-   Direct replacement for Variomod XC modules for EMH meters
-   Auto reads EMH meters and maps values in predefined MODBUS register table
-   Configurable Modbus address via Modbus Commands 
-   Configurable Reading Period on IEC6056-21 side via Modbus Commands
-   Configurable Reading Table Number on IEC6056-21 side via Modbus Commands 
-   Gets power directly from meter
-   Serial interface directly connected to meter ( with 15kV ESD protection)
-   Wide operating temperature range from -40 to 85 °C 
-   Customization of reading process and register tables based on client request
-   Firmware upgradable over serial line

MODBUS RTU AND IEC62056-21 CHARACTERISTICS
Modbus RTU Address
Default value is 0x01
Changeable via Modbus Command
Reading Period on IEC62056-21 Protocol Meter Side
Default value is 10 (in seconds)
Changeable via Modbus Command
IEC62056-21 Protocol Meter Read Out Table
Default value is 0x30 = ‘0’in ASCII
Changeable via Modbus Command
IEC62056-21 Protocol Meter Reading Method
Read each line of table and register data during reading
IEC62056-21 Protocol Meter Read Out Data
Date
Time
Import and Export Active Energy
Import and Export Reactive Energy
Reactive Energy in 4 Quadrants
Import and Export Maximum Demands
Active Power
Phase Currents for each phase
Phase Voltages for each phase
Frequency
Error Code
Extendable/Changeable via firmware change
Monitoring Parameters

IEC Read counter
Time counter (in seconds)
FW version
Query able via Modbus Commands



INTERFACE AND INDICATORS
RS485 Connector
Terminal Connector for 2 wire RS485 connection and GND on Modem Side
Operation Mode Selection Switch
Selects the operating mode of the device.


Mode Selection
Modem Side Communication Parameters
Meter Side Communication Parameters
Mode 1 (LED 1 ON)19200 8N1
Starts with 300 baud rate and changes during transmission to target baud rate based on IEC62056-21 protocol
Mode 2 (LED 2 ON)
9600 8N1
Starts with 300 baud rate and changes during transmission to target baud rate based on IEC62056-21 protocol
Mode 3 (LED 3 ON)
19200 8N1
19200 7E1 Fixed
Mode 4 (LED 4 ON)
9600 8N1
9600 7E1 Fixed
LED Indicators
Following LEDs available to show system status.
1 – Mode 1 LED
2 – Mode 2 LED
3 – Mode 3 LED
4 – Mode 4 LED
5 – System LED: Blinks every second
6 – Tx LED: Sending data from Modem Side to Meter Side
7 – Rx LED: Receiving data from Meter Side to Modem Side


FIRMWARE UPGRADE
Upgrade over Serial Line
Available from Modem side Serial Line
RS485 on LKM614


Device must be on operating mode 19200 8N1 for firmware upgrade process.




POWER
Power Input
Gets power directly from Meter


PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
Enclosure
ABS, IP51
Dimensions
105x 45 x 27(h x w x d) mm
Weight
~60gr
Storage Temperature
-55 to 125 °C
Operating Temperature
-40 to 85 °C 
Operating Humidity
5% to 95%Non-condensing


LKM614: Modbus RTU to IEC 62056-21 Protocol Meter gateway specially designed for EMH LZQJ-XC Meter with RS485 on Modem Side

BSB Series Industrial Unmanaged Ethernet Switch
BSB Series Industrial Unmanaged Ethernet Switch
TLM Series LoRa and LoRaWAN Modems
TLM Series LoRa and LoRaWAN Modems
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
LKM Series Electricity Meter Protocol to Modbus Protocol Gateways
CKL Series Modbus, Serial to Ethernet Gateway
CKL Series Modbus, Serial to Ethernet Gateway
STG Series WMBus (Wireless MBus) - Modbus TCP/RTU Gateway
STG Series WMBus (Wireless MBus) - Modbus TCP/RTU Gateway
HUR Series Modbus TCP and RTU Remote I/O Devices
HUR Series Modbus TCP and RTU Remote I/O Devices
MBC Series IEC62056-21 Protocol Auto Baud Changer
MBC Series IEC62056-21 Protocol Auto Baud Changer
KMK Series Optical Probes for Energy Meters
REDZ Software Solutions